Racewell Sheep Handlers

Racewell Sheep Handler wont turn on or go.

  1. Check the 12v adaptor cord is firmly connected
  2. Check all extension cords and cord connections
  3. Check for external damage to the 12V adaptor and using a multimeter check the adaptor output is at least 11 volts
  4. Check the On/Off switch and wiring to it
  5. Check wiring generally for breaks or chew marks
  6. Check the air lines and compressor is turned on.

Docking Irons

My docking iron does not get hot enough.

  1. Clean inside burner tube. Insect nests or spider webs are sometimes found inside the burner tube. These restrict the gas flow and need to be cleaned out with a small rag or small brush
  2. Clean jet. The best way to clean a jet is by dropping it into a jar of boiling water. This removes the waxy type build-up which can occur. If unit still does not perform then replace jet (refer Parts List for correct Part No).
  3. Jet can also be pricked with 5 amp fuse wire - do not drill jet.

Docking Iron will not light

  1. Ensure the gas bottle is attached correctly, has sufficient gas in it and all fittings are tightened.
  2. Clean jet. The best way to clean a jet is by dropping it into a jar of boiling water. This removes the waxy type build-up which can occur. If unit still does not perform then replace jet (refer Parts List for correct Part No).
  3. Jet can also be pricked with 5 amp fuse wire - do not drill jet.

The Docking Iron sends a long wavery yellow flame out the end of the searing head

Clean inside burner tube. Insect nests or spider webs are sometimes found inside the burner tube. These restrict the gas flow and need to be cleaned out with a small rag or small brush

LPG Dehorners

Dehorner does not get hot enough

  1. Clean inside burner tube. Insect nests or spider webs are sometimes found inside the burner tube. These restrict the gas flow and need to be cleaned out with a small rag or small brush
  2. Clean jet. The best way to clean a jet is by dropping it into a jar of boiling water. This removes the waxy type build-up which can occur. If unit still does not perform then replace jet (refer Parts List for correct Part No).
  3. Jet can also be pricked with 5 amp fuse wire - do not drill jet.

LPG Dehorner will not light

  1. Ensure the gas bottle is attached correctly, has sufficient gas in it and all fittings are tightened. 
  2. Clean jet. The best way to clean a jet is by dropping it into a jar of boiling water. This removes the waxy type build-up which can occur. If unit still does not perform then replace jet (refer Parts List for correct Part No).
  3. Jet can also be pricked with 5 amp fuse wire - do not drill jet.

Dehorner sends a long, wavery yellow flame out the end of the Dehorner head.

Clean inside burner tube. Insect nests or spider webs are sometimes found inside the burner tube. These restrict the gas flow and need to be cleaned out with a small rag or small brush

Dosing Gun

My Dosing Gun comes up with a stall error when I use it

1: The Gun has a built-in stall feature to prevent overloading. Try reducing the piston speed forward using the menu button on the keypad.

2: Remove the barrel and valves (inlet and outlet) and make sure everything is clean and moves freely.

3: Check the drive thread. Remove the barrel and pull the trigger and see if the gun stalls. If it stalls without the barrel it could be a tight drive thread. The drive thread is self-lubricating, however, a small drop of oil could help. If the drive thread is tight and makes the motor labor, then the drive thread and piston should be replaced.

4: If the Gun still stalls then take note of where the piston is stalling and contact Te Pari. If it is stalling on the return stroke there could be an issue with the magnet sensor in the piston which detects the home position. Contact Te Pari for support.

My dosing gun is showing Error 94, c08 10, power off

1: Put the gun into update mode by holding the down button then quickly pressing the on button.

2: After the 4th bar loads and the screen shows upgrade, turn it off then on again.

3: We recommend updating the firmware as well, as per the attached video.

title

My dosing gun shows Error 56

This is when you have the wrong barrel on the gun. Follow this video to change the barrel.

title

My Dosing Gun is showing Error 49

This is a Wifi connection issue and is fixed by updating the firmware. Watch this video: 

title

Scales

My Loadbar cables need to be replaced.

Replacing the cables needs specialised equipment. Send the Loadbars into Te Pari Products with your full contact details included. We will then contact you with a quote for the repair. Te Pari contact details are on the Contact Us page of this website